T1 - Absence of significant postdefibrillation bradyarrhythmias in patients with automatic implantable defibrillators
AU - Niazi, Imran
AU - Kadri, Nazih
AU - Mahmud, Rehan
AU - Jazayeri, Mohammad
AU - Denker, Stephen
AU - Werner, Paul
AU - Akhtar, Masood
AU - Tchou, Patrick
PY - 1988/4
Y1 - 1988/4
N2 - Because postdefibrillation bradycardia or asystole is of clinical concern in patients with implanted automatic cardioverter defibrillators, we analyzed the cardiac rhythm after 157 intraoperative defibrillations in 50 patients undergoing implantation of the device. Factors that could influence the heart rhythm immediately after defibrillation were also analyzed. The postdefibrillation heart rate and the duration of postdefibrillation asystole did not correlate with age, conduction abnormalities, type or duration of arrhythmia before defibrillation, delivered energy, lead system, or left ventricular ejection fraction, but they did correlate with the resting preoperative heart rate and the concomitant performance of coronary artery bypass surgery at the time of defibrillator implantation. Temporary pacing (for prolonged asystole) was required in only two patients, both of whom had also undergone bypass surgery. Fourteen patients being treated with amiodarone had slower resting and postdefibrillation heart rates, but the mean duration of postdefibrillation asystole was similar to that seen in patients not receiving any antiarrhythmic medication. On follow-up, 25 monitored and 178 unmonitored automatic defibrillator discharges occurred in 24 patients, without evidence of symptomatic postdefibrillation bradyarrhythmias. Thus significant postdefibrillation bradyarrhythmias were uncommon, but when such a propensity existed it could not be predicted reliably on clinical grounds alone.
AB - Because postdefibrillation bradycardia or asystole is of clinical concern in patients with implanted automatic cardioverter defibrillators, we analyzed the cardiac rhythm after 157 intraoperative defibrillations in 50 patients undergoing implantation of the device. Factors that could influence the heart rhythm immediately after defibrillation were also analyzed. The postdefibrillation heart rate and the duration of postdefibrillation asystole did not correlate with age, conduction abnormalities, type or duration of arrhythmia before defibrillation, delivered energy, lead system, or left ventricular ejection fraction, but they did correlate with the resting preoperative heart rate and the concomitant performance of coronary artery bypass surgery at the time of defibrillator implantation. Temporary pacing (for prolonged asystole) was required in only two patients, both of whom had also undergone bypass surgery. Fourteen patients being treated with amiodarone had slower resting and postdefibrillation heart rates, but the mean duration of postdefibrillation asystole was similar to that seen in patients not receiving any antiarrhythmic medication. On follow-up, 25 monitored and 178 unmonitored automatic defibrillator discharges occurred in 24 patients, without evidence of symptomatic postdefibrillation bradyarrhythmias. Thus significant postdefibrillation bradyarrhythmias were uncommon, but when such a propensity existed it could not be predicted reliably on clinical grounds alone.
UR - https://www.scopus.com/pages/publications/0023906634
UR - https://www.scopus.com/inward/citedby.url?scp=0023906634&partnerID=8YFLogxK
U2 - 10.1016/0002-8703(88)90886-1
DO - 10.1016/0002-8703(88)90886-1
M3 - Article
C2 - 3354412
AN - SCOPUS:0023906634
SN - 0002-8703
VL - 115
SP - 830
EP - 836
JO - American Heart Journal
JF - American Heart Journal
IS - 4
ER -